18 K12 Installation & User Manual
ENG
Set opening time
The opening time determines for how long the
lock should remain open following a correct
entrance code. When K12 is delivered the open-
ing time is 7 seconds for both relays.
Enter A28.
Enter the desired opening time (01-99) us-
ing two digits, e.g. 09 for 9 seconds.
Set door held warning time
If the door is still open when the opening time
has expired, a buzzer sounds as to remind
the visitor to close the door immediately – or
the alarm output will be activated. The buzzer
sounds until the door is closed.
Note that door contacts must be connected and
that Door control must be activated for this to
work.
This is how to change the door held warning
time, if needed:
Enter A29.
Enter the desired door held warning time
(01-99) with two digits, e.g. 09 for 9 sec-
onds. .