123456789okF2F10CAlgoRexAlarms FaultsIsolationInformationAlarm device Alarm deviceAlarm devicePremisesactive faultisolate(d)mannedRemote alarm Remote
e195511.199910Siemens Building TechnologiesCerberus DivisionNormal operation / Mains availableWhat is «Normal operation»?The system is ready for rec
e195511.199911Siemens Building TechnologiesCerberus DivisionOperating states ’manned’ and ’unmanned’Is the Cerberus Alarm Concept activated? Yes No
e195511.199912Siemens Building TechnologiesCerberus DivisionQuick reference instructionsHow to start operating ?1. Press F2Ü The MAIN MENU is displaye
e195511.199913Siemens Building TechnologiesCerberus DivisionCerberus Alarm ConceptHow does the Cerberus Alarm Concept function?When the system operate
e195511.199914Siemens Building TechnologiesCerberus DivisionAlarm – general informationHow are alarm messages shown in the text display?RoomRoomCorrid
e195511.199915Siemens Building TechnologiesCerberus DivisionAlarm – general informationcont.Message orderMessages are presented in the following order
e195511.199916Siemens Building TechnologiesCerberus DivisionAlarm – what to do ?AlgoRex FIREFIGHTER FACILITY" 'FIRE BRIGADE in 4:31 (min)&ap
e195511.199917Siemens Building TechnologiesCerberus DivisionAlarm – what to do ?cont.What to do if alarm cannot be reset ?As long as a detector still
e195511.199918Siemens Building TechnologiesCerberus DivisionDetector zone, temporary isolationWhat is ISOLATION of a ZONE ?Isolated zones have the fol
e195511.199919Siemens Building TechnologiesCerberus DivisionDetector zone, temporary isolationcont.5. Press F1Ü The FUNCTION LIST ’zone’ is displayedS
Data and design subject to changewithout notice. / Supply subject toavailability.E Copyright bySiemens Building Technologies AGWe reserve all rights i
e195511.199920Siemens Building TechnologiesCerberus DivisionIsolation of individual detectorsWhen does a detector have to be isolated ?Only when it is
e195511.199921Siemens Building TechnologiesCerberus DivisionFaultWhat to do in case of reported fault messages?1. Confirm the message by pressing ACK2
e195511.199922Siemens Building TechnologiesCerberus DivisionMode ’Detector test’What is the «Detector test» mode for?The mode «Detector test» allows
e195511.199923Siemens Building TechnologiesCerberus DivisionMode ’Detector test’cont.Recommendations for detector test Perform the function test perio
e195511.199924Siemens Building TechnologiesCerberus DivisionMode ’Detector test’cont.Terminate «Detector test» for all detector zones within a SECTION
e195511.199925Siemens Building TechnologiesCerberus DivisionMode ’Detector test’cont.Poll ’test alarms’ in the event memory1. Press F2Ü The MAIN MENU
e195511.199926Siemens Building TechnologiesCerberus DivisionMode ’Installation test’What is the mode «Installation test» for?The mode «Installation te
e195511.199927Siemens Building TechnologiesCerberus DivisionMode ’Renovation’What is the «Renovation» mode for?In «Renovation» mode, automatic detect
e195511.199928Siemens Building TechnologiesCerberus DivisionRemote transmission ISOLATE/DE–ISOLATEThis system is equipped with a remote transmission f
e195511.199929Siemens Building TechnologiesCerberus DivisionAlarm devices ISOLATE/DE–ISOLATEWhen do alarm devices (horns, sirens, etc.) have to be iso
e195511.19993Siemens Building TechnologiesCerberus DivisionOperating instructions CI1145Introduction 4. . . . . . . . . . . . . . . . . . . . . . . .
e195511.199930Siemens Building TechnologiesCerberus DivisionPrinter ISOLATE/DE–ISOLATEThis system is equipped with a printer Yes NoWhen does the pr
e195511.199931Siemens Building TechnologiesCerberus DivisionPrinter B2Q191: paper replenishingValid for this system Yes, system equipped with printe
e195511.199932Siemens Building TechnologiesCerberus DivisionLamp testWhat is the «Lamp test» used for?For testing the correct functioning of all indic
e195511.199933Siemens Building TechnologiesCerberus DivisionAlarm counterWhat is the purpose of polling the alarm counter?The alarm counter shows the
e195511.199934Siemens Building TechnologiesCerberus DivisionEvent memoryPolling event memory of an ’AREA’1. Press F2Ü The MAIN MENU is displayed2. Pre
e195511.199935Siemens Building TechnologiesCerberus DivisionSet clock and dateNormally the date and time do not have to be corrected!The date and time
e195511.199936Siemens Building TechnologiesCerberus DivisionOverview operating menusTo enter ’MAIN MENU’ press F2FUNCTION LIST ’area’switching MANNED
e195511.199937Siemens Building TechnologiesCerberus DivisionOverview operating menuscont.To enter ’MAIN MENU’ press F2FUNCTION LIST ’area’switching M
e195511.199938Siemens Building TechnologiesCerberus DivisionOverview operating menuscont.To enter ’MAIN MENU’ press F2FUNCTION LIST ’area’switching M
e195511.199939Siemens Building TechnologiesCerberus DivisionOverview operating menuscont.To enter ’MAIN MENU’ press F2FUNCTION LIST ’area’switching M
e195511.19994Siemens Building TechnologiesCerberus DivisionIntroductionThis Cerberus fire detection installation consists of the following components:
e195511.199940Siemens Building TechnologiesCerberus DivisionOverview operating menus cont.To enter ’MAIN MENU’ press F2F1FUNCTION LIST ’terminal’poll
e195511.199941Siemens Building TechnologiesCerberus DivisionOverview operating menus cont.To enter ’MAIN MENU’ press F2Noteok = presslogical address
Back_e195511.199942Siemens Building TechnologiesCerberus DivisionSiemens Building TechnologiesCerberus DivisionSiemens Building Technologies AGCerberu
e195511.19995Siemens Building TechnologiesCerberus DivisionOperating accessGeneral:The control console is protected by a front door against unauthoriz
e195511.19996Siemens Building TechnologiesCerberus DivisionControl console layout123456789okF2F10CAlgoRexRAlarms FaultsIsolationInformationAlarm devic
e195511.19997Siemens Building TechnologiesCerberus DivisionControl console layoutcont.Firefighter facility17 Text display with yellow illumination. d
e195511.19998Siemens Building TechnologiesCerberus DivisionMessage categoriesThere are the following message categories:Alarms danger messages acqui
e195511.19999Siemens Building TechnologiesCerberus DivisionTerminology ’Area’, ’Section’ and ’Zone’What is an «Area»?It normally covers a whole buildi