Remote Mount Form Factor
5-7
SIMATIC Panel PC 670 / 870 Operating Unit, Equipment Manual
Edition 07/02
5.2.3 Mounting
The operating unit is supplied as a complete combination: operating unit with mounting
plate, on which the receiver is mounted, on the rear panel.
The procedure for installation in a cabinet or housing is the same as that described in
Chapter 3.
The mounting depth has to be taken into account (refer to Figure 5-4).
It results from D + 48,6 mm + 10 mm (10 mm additional space for ventilation).
With a Panel PC 670/870 in remote mount form factor, the operating unit can be ope-
rated in an inclined position of up to 70°.
Note
Please note the correct installation of the strain relief devices for the connecting ca-
bles.