7 Appendix
7.1 Appendix A: Standard User Settings
The operational features of the SPC systems are described below. The installation
engineer will inform users rights assigned to each user profile. Depending on how
the system has been programmed, users may have rights to all or some of these
features.
Operation User Profile
Default
Description
FULLSET
Limited
Standard
Manager
The FULLSET operation fully sets the alarm system and provides full protection
to a building (opening of any alarm zones activates the alarm).
On selecting FULLSET, the buzzer sounds and the Keypad display counts down
the exit time period. Exit the building before this time period has expired.
When the exit time period has expired, the system is set and opening of
entry/exit zones starts the entry timer. If the system is not Unset before the entry
timer expires, the alarm is activated.
To perform a FULLSET, see
5.1.
PARTSET A
Standard
Manager
The PARTSET A option provides perimeter protection to a building while
allowing free movement through the exit and access areas.
Zones that have been classified as EXCLUDE A remain unprotected in this
mode. By default, there is no exit time; the system sets instantly on selection of
this mode. An exit timer can be applied to this mode by enabling the Partset A
timed variable.
To perform a PARTSET A, see Section
5.2.
PARTSET B
Standard
Manager
The PARTSET B option applies protection to all zones except those that have
been classified as EXCLUDE B.
By default there is no exit time; the system sets instantly on selection of this
mode. An exit timer can be applied to this mode by enabling the Partset B timed
variable.
To perform a PARTSET B, see Section
5.3.
FORCESET
Standard
Manager
The FORCESET option is presented on the Keypad display when an attempt is
made to set the system while an alarm zone is faulty or still open (the top line of
the display shows the open zone).
Selecting this option sets the alarm and inhibits the zone for that set period.
To perform a FORCESET, see Section
5.5.
UNSET
Limited
Standard
Manager
The UNSET operation unsets the alarm. This menu option is only presented on
the Keypad after an alarm has been activated and a valid user code has been
entered.
To UNSET the system, see Section
5.6.
RESTORE
Standard
Manager
The RESTORE operation restores an alert condition on the system and clears
the alert message associated with that alert condition.
An alert condition can only be restored after the zone(s) or fault(s) that triggered
the alert condition have been restored to their normal operating state and the
RESTORE option in user programming is selected for that zone.
To RESTORE an alert, see Section
5.7.
Tab. 4 Standard User Settings