Siemens HC15 User Manual Page 25

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 24
AN39: USB Interface Description
4.2 Composite Device Enumeration for “Mdm“ Variant
28
s
HC15_USB_Interface_v02 Page 25 of 28 2007-04-05
Confidential / Preliminary
Endpoint Descriptor
4.2.2.3 Interface 1 (MODEM port: CDC ACM Data)
Endpoint Descriptor
Table 30: MDM\Configuration Descriptor\Interface0\Endpoint Descriptor
Name Value Dec Hex
bFunctionLength Valid 7 0x07
bDescriptorType ENDPOINT 5 0x05
bEndpointAddress 1 IN
1
1.
Given endpoint address is an example and can be changed without notice.
129 0x81
bmAttributes.TransferType Interrupt 3 0x03
wMaxPacketSize 16 16 0x0010
bInterval 32 frames (32ms)
2
2.
Given interval is an example and can be changed without notice.
32 0x20
Table 31: MDM\Configuration Descriptor\Interface1
Name Value Dec Hex
bLength Valid 9 0x09
bDescriptorType INTERFACE 4 0x04
bInterfaceNumber 1 1 0x01
bAlternateSetting 0 0 0x00
bNumEndpoints 2 2 0x02
bInterfaceClass Communication Data 10 0x0A
bInterfaceSubClass 0 0x00
bInterfaceProtocol None 0 0x00
iInterface 3 3 0x03
Table 32: MDM\Configuration Descriptor\Interface1\Endpoint Descriptor
Name Value Dec Hex
bFunctionLength Valid 7 0x07
bDescriptorType ENDPOINT 5 0x05
bEndpointAddress 2 IN
1
1.
Given endpoint address is an example and can be changed without notice.
130 0x82
bmAttributes.TransferType Bulk 2 0x02
wMaxPacketSize 64 64 0x0040
bInterval 0 0x00
Page view 24
1 2 ... 20 21 22 23 24 25 26 27 28

Comments to this Manuals

No comments