GAS CHROMATOGRAPHY p processADVANCE NETWORK COMMUNICATIONS BOARD/DATANET (ANCB/DN) User’s Manual Edition 1/2007
Safety Practices and Precautions, Continued Correct Operating Voltage Before switching on the power, check that the operating voltage listed on the e
Chapter 1 Installation Overview Description The Advance Network Communications Board DataNET (ANCB/DN) board plugs into the backplane of an Advance M
Overview, Continued Figure 1 shows Advance Maxum and Advance Optichrom GC’s communicating on an ACS via a DataNET link. Advance MaxumApplied Automati
ANCB/DN Specifications Protocol and Addressing Open Systems standard TCP/IP protocol and addressing (Transmission Control Protocol/Internet Protocol
ANCB/DN Specifications, Continued Cable Types The following Table should be used when evaluating or selecting cable for an existing or new installati
ANCB Installation Description The ANCB is installed into slot 1 of the Advance Maxum’s or NAU’s System Controller (SYSCON). To install the ANCB it i
ANCB Installation, Continued Instructions, continued Step Procedure 4. Press the ANCB straight into slot 1. Make sure that you push evenly on b
Site Wiring Requirements Description The type of wiring is dependent upon the site requirements: • CE (Conformite Europeene) Certified Areas • NEC
Site Wiring Requirements, Continued DataNET Channels The DataNET channel connections can be either copper wire or fiber optic cable. The wiring metho
Site Wiring Requirements, Continued Table 1-1: Recommended DataNET Cable, Continued Cable Type Vendors & P/N Installation Notes Twisted Pair
Site Wiring Requirements, Continued Use approved flexible non-metallic conduit wiring method. Conduit may contain multiple cables. For CE installatio
CE Installations Description This section should be used for installation sites that must conform to CE (Conformite Europeene) Certification. Typical
CE Installations, Continued 3. A split ferrite filter must be clamped to DataNET copper wire and fixed immediately to the outside of the unit; use p
DataNET Connections Description This section provides instructions for connecting a Maxum or NAU to a DataNET network. All DataNET connections are ma
DataNET Copper Connections Before You Begin This section provides instructions for connecting the Maxum to a DataNET network. All DataNET connections
DataNET Copper Connections, Continued Instructions, continued Step Action 3. Strip the insulation ¼ -inch back from each of the incoming copper
DataNET Fiber Optic Connections The Fiber Optic Coupler is mounted in a threaded, potted, gas tight fitting assembly designed for use in hazadrous ar
DataNET Fiber Optic Connections, Continued The DataNET Fiber Optic Couplers use ST-style connectors (twist & lock). Always insure that the TX (T
DataNET Fiber Optic Connections, Continued Installation Instructions Step Action 1. Ensure that the ANCB is installed in slot 1 of the SYSCON. 2.
DataNET Fiber Optic Connections, Continued Instructions, continued Step Action 4. Connect the incoming Fiber Optic cable transmit and receive lin
Advance Network Communications Board/DataNET (ANCB/DN) Revised Printing – January 2007 User’s Manual 2000592-001
Chapter 2 Data Communications Setup Introduction Overview This chapter provides maintenance personnel instructions for making the operational setting
Configuring Your PC Description The Advance Network Communications Board (ANCB) has a built-in utility for configuring the unit. The Windows® HyperTer
Configuring Your PC, Continued 5. Click OK. The Connect To dialog box opens. 6. From the Connect using scroll list choose the COM port you will be
Configuring Your PC, Continued 8. Scroll each field and select the following Port Settings: Bits per second: 57600 Data Bits: 8 Parity: None Stop bi
Configuring Your PC, Continued 11. Click Settings tab. The settings screen will appear. 12. From the Emulation scroll list select VT100. Do not cha
Configuring Your PC, Continued 14. Ensure that the following default settings are set: Cursor: • Underline √ Blink Terminal Mode: none Character set:
Establishing a Connection Description Once your PC is set up, as described in Configuring Your PC, you are ready to connect to the Advance Maxum or N
Establishing a Connection, Continued Password Format A password name can consist of any combination of alphanumeric characters. The alphanumeric name
Establishing a Connection, Continued 3. At the > prompt type: login password and press ↵ Enter. The Connect Screen will appear with the login inf
Copyright Notice © 2002-2007 by Siemens All rights reserved. This publication is for information only. The contents are subject to change without noti
Setting Network Address Description This section provides instructions to configure the ANCB/DN. Command Line Definitions Chapter 3, Command Line Su
Setting Network Address, Continued See Assigning an IP Address, page 32 to learn how to assign an IP Address. Learning Hint 4. To configure the ANC
Assigning an IP Address Overview Each DataNET device must have a unique IP address. This 32-bit number defines each devices network ID and host ID. T
Firmware Updates Description Periodically we will provide our users with firmware upgrades. Perform the following instructions to download a new firm
Firmware Updates, Continued 6. Click on Send Text File. The Send Text File dialog box will appear. Choose the directory on your PC where the ANCB fi
Chapter 3 Command Summary Command Descriptions Description This chapter is intended for maintenance personnel. This chapter provides definitions for
Command Descriptions, Continued logout Log out of device. netstat hdlc Display DataNET link statistics for all ports. netstat hdlc clear Display and
Command Descriptions, Continued config address ip This command sets the device IP address. Each device in the system must have a unique IP address.
Command Descriptions, Continued display links This command displays the ANCB/DN link state table. The link state table indicates, for each link, whet
Command Descriptions, Continued “hdlc” Command This command may be used to override default values for several parameters related to the DataNET pr
Table of Contents Preface iiiTechnical Support ivSafety Practices and Precautions v Chapter 1: Installation 1Overview 1ANCB/DN Specifications
Command Descriptions, Continued download Use this command to load new software into the device via the RS-232 Configuration port. The procedure for s
Command Descriptions, Continued local> list 155 msg | source | destination | size | source port | time stamp 155 | Trace e
Command Descriptions, Continued login The login command allows the user to access all the ANCB parameters and diagnostic information. The format is:
Command Descriptions, Continued Example: local> netstat dn 1 DataNET Statistics for DN link 1 Frames Sent 855 Frames Sent/Retried 0 Frame
Command Descriptions, Continued reset This command resets and saves the configuration parameters in non-volatile memory. test This command places a
Chapter 4 Troubleshooting Introduction Overview This chapter provides installation personnel with troubleshooting information to solve problems assoc
ANCB Description Description The DataNET ANCB (Advance Network Communication Board) provides the communications electronics for the unit. The ANCB plu
ANCB Description, Continued Jumper J2 Settings The ANCB provides a set of impedance matching jumpers to simplify the cable interfacing process. Jump
ANCB Description, Continued Jumper J5 Settings The ANCB jumper settings for J5 are factory set and dependent upon the product the ANCB will be used i
ANCB LEDs Description and Operation Description This section provides maintenance personnel with information on how to use the ANCB LEDs for troubles
ANCB LEDs Description and Operations, Continued Figure 4-2 shows the edge visible LEDs on the ANCB. The LED labels are silk-screened adjacent to each
ANCB LEDs Description and Operations, Continued ANCB Ethernet Controller LEDs Each ANCB provides two Ethernet ports a 10BaseT and 10Base2. Each port
DataNET Troubleshooting Guide Instructions If a DataNET communications link fails to establish check for a: • configuration conflict, • link signal
DataNET Troubleshooting Guide, Continued Configuration Parameter Errors The device may have an invalid or duplicate IP address, Subnet mask or iprou
DataNET Troubleshooting Guiding, Continued If the ANCB_DN port LED is never green, or intermittently flashes between green and red, there may be a si
Chapter 5 Parts Catalog Introduction Overview This chapter is intended for maintenance personnel. The Chapter provides a list of replaceable parts an
Available Parts Description The following spare parts are available. Part Description Ordering Number ANCB Communication Board; DataNET 2020951-004
Glossary Definitions Overview This section defines important Terms. The Advance Network Gateway Ethernet (ANG_EN) is a wall- (or rack-) mounted unit
Definitions, Continued A Late Collision is one that occurs after the first 64 bytes in a frame or packet. Since the smallest Ethernet frame (packet)
Preface Audience & Purpose This manual is intended for maintenance personnel and describes how to install the Advance Network Communication Boar
Siemens Energy & Automation, Inc. 7101 Hollister Road, Houston, TX 77040 Phone 713-939-7400, Fax 713-939-9050
1/2007 Edition 2000592-001Siemens Energy & Automation, Inc.7101 Hollister Road, Houston, TX 77040United StatesPhone +1 (713) 939-7400Fax +1 (713
Technical Support Getting Help At Siemens Energy & Automation, Inc. we take pride in the on going support we provide our customers. When you purch
Safety Practices and Precautions Safety First This product has been designed and tested in accordance with IEC Publication 1010-1, Safety Requiremen
Comments to this Manuals